Total Residential Package
For Installation at the Service Entrance



Compare clamping voltage and surge current. Greater performance is always worth a little extra expense.

LA 302R

CA 302R

TA 304

Weatherproof Enclosure N-4
CASE DIMENSIONS:
2-1/4" Diameter
2-1/4" High

Weatherproof Enclosure N-4
Case DIMENSIONS:
2-1/4" Diameter
4-1/2" High

Weatherproof Enclosure N-4
Case DIMENSIONS:
5.2" Diameter
1.9" High

125/250 Volts: Single Phase
Surge Current: 60,000 A
Joules: 2,000 per Pole
Operations: No Limit
Leak Current: None
Leads: 18" #12 AWG

This unit is designed for service such as single phase commercial and residential entrance panels.
Whole House Protection

INSTALLATION:
Fasten arrestor in place. Use a Delta mounting bracket, part # MB, a pipe strap, or a knockout hole. Connect the black wire to the hot line at any convenient point load-side of an existing fuse or circuit breaker. Connect the white wire to an existing ground system and the grounded metal frame work of the equipment to be protected or make a ground source per NEC Article 250.

125/250Volt, Single Phase Surge Capacitor to be used where additional protection is needed.

INSTALLATION:
Connect the black wires below the fuses or breaker. Connect the white wire to the ground and/or neutral bus.

Two Pair, data line circuit protector w/separate ground.
Unlimited number of surges.
Max. Energy: 750 Joules per Line
Response Time: 5 Nanoseconds
Leads: 15" #22 SOL
Telephone/Modem protection

INSTALLATION:
This device is to be wired in parallel to the telephone line or low voltage circuit. This can be done by punching down the AWG22 solid lead wires to a punch down block or by making a parallel connection to the screw terminal. All lead wires should be cut as short as possible. This device is non-polar. Double-sided adhesive tape is provided for securing the device to any surface. Connect the green ground wire on the unit to a physical ground. Use only 1 ground point per system. Solder all ground connections whenever possible. Run ground wire in the shortest path towards earth. The protector is rate 230VDC.

LA 302-R Pricing

CA 302-R Pricing

TA 304 Pricing

Shipping amounts posted are for shipping within the contiguous U.S. only.
Please call for freight costs outside the contiguous U.S.

 

Available with separate ground add part No. "G"


 

Order Your Products Now Installation Instructions Information Request Form

Home General Products Service Site Map

Please give us your feedback on our website.

© 2004 Delta Lightning Arrestors